Print Technical Specification. Manuals and Warranties. Size KB. The VA of the multiple units can be combined, then doubled, to get a maximum VA the customer is eligible to trade up to.
Additional items can only include Surge products, or UPS accessories relative to the application level of the UPS s that are being purchased. Technical support Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.
Easy to install Innovative design allows for fast, easy installation by almost anybody. User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. LED Indicators Provide easy-to-read status of the unit and utility power conditions.
Serial connectivity Provides management of the UPS via a serial port. Pure sine wave output on battery Simulates utility power to provide the highest degree of compatibility for active PFC power factor corrected servers and sensitive electronics. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Product Distribution Canada, United States. Technical Specifications Print. Max Configurable Power Watts 1. Topology Line interactive. Waveform type Sine wave.
Input voltage range for main operations 75 - Adjustable, 82 - V. Number of Power Cords 1. Avoids costly power problems by keeping your IT equipment and data safe and available Network grade power conditioning protects from damaging surges and disruptive noise. Reliable battery back-up capacity to power through outages or gracefully shutdown systems. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging.
Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Smarter productivity with ability to tailor to your specific application needs Intuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys.
Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications. Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Disconnected battery notification Warns when a battery is not available to provide backup power.
Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Boost and Trim Automatic Voltage Regulation AVR Gives higher application availability by correcting low and high voltage conditions without using the battery not available on all models. Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power.
Resettable circuit breakers Enables a quick recovery from overload events. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance. User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR.
Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Predictive failure notification. Provides early-warning fault analysis ensuring proactive component replacement. Transfer Time 4 ms typical : 8 ms maximum.
Input voltage range for main operations 75 - Adjustable, 82 - V. Number of Power Cords 1. Battery type Lead-acid battery. Typical recharge time 3hour s. Replacement Battery RBC Expected Battery Life years 3 - 5. RBC Quantity 1. Battery Charge Power Watts Watts. Runtime View Runtime Graph. Efficiency View Efficiency Graph. Control panel LED status display with on line : on battery : replace battery and overload indicators, Multifunction LCD status and control console.
Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm. Surge Protection and Filtering. Surge energy rating Joules. Maximum Height 3. Maximum Width Maximum Depth Net Weight Shipping weight Shipping Height Shipping Width Shipping Depth Color Black. Units per Pallet 8. Operating Elevation 0 - ft 0 - meters.